INPAL Energie leader des tubes acier pré-isolés chauffage urbain froid urbain fluides haute et basse température
Glossary
Downloads
News
en
fr
en
Search:
INPAL Energy
Presentation
History
Our Sites
Management System
Commitments
Quality
Professional Organisations
Sustainable Development
Our Commitments
Energy efficiency
Operation of a district heating network
Products
Rigid systems
Flexible systems
Monitoring systems
Geolocalisation
Accessories
Applications
District heating
District cooling
Industry
Specific applications
Our references
Services
Project Management
Owners Support
Studies and Calculations
Technical Support
Training
Contact us
INPAL Energie leader des tubes acier pré-isolés chauffage urbain froid urbain fluides haute et basse température
Products
Rigid systems
Flexible systems
Monitoring systems
Geolocalisation
Accessories
Polyuretub 130 accessories
ISOPAL accessories
Threaded PEX-PEX couplers - 6/10 bar
Crimped PEX-PEX couplers - 6/10 bar
Coupler with weld-on nozzle - 6/10 bar
Coupler with threaded end - 6/10 bar
90° couplers - 6/10 bar
Tee couplers - 6/10 bar
Half-shells for branches (Tees)
Junction muff
Heat-shrink end cap
Wall crossing
TUCAL accessories
ISOPAL accessories
Threaded PEX-PEX couplers - 6/10 bar
Description : Threaded PEX-PEX couplers are used in sanitary applications and at junctions accessible in buildings or in wells. Threaded PEX-PEX couplers are made from robust high-quality brass in compliance with DIN 8076. Technical features and installation instructions for ISOPAL accessories are provided in the ISOPAL (...)
> More
Crimped PEX-PEX couplers - 6/10 bar
Description : Crimped PEX-PEX couplers must be used in buried sections and preferably in heating installations (6 bars). Crimped couplers are made from: St 37.0 S, material No. 1.0254, according to DIN 2448, dezincification-resistant brass CZ 132, red brass RG 7. Threaded unions are made from robust high-quality brass in compliance with DIN 8076. Technical features and installation (...)
> More
Coupler with weld-on nozzle - 6/10 bar
Description : ISOPAL crimped couplers must be used in buried sections and preferably in heating installations (6 bars). Crimped couplers, with weld-on nozzle, are made from: St 37.0 S, material No. 1.0254, according to DIN 2448, dezincification-resistant brass CZ 132, red brass RG 7. Threaded unions are made from robust high-quality brass in compliance with DIN 8076. Technical features (...)
> More
Coupler with threaded end - 6/10 bar
Description : All connections (G) are made with a threaded end in compliance with standard DIN 2999 for assembly on the next pipe. The corresponding threaded nut in compliance with standard DIN 2986 is supplied separately. Threaded couplers are used in sanitary applications and at junctions accessible in buildings or in wells. ISOPAL threaded couplers are made from robust high-quality brass (...)
> More
90° couplers - 6/10 bar
Description : ISOPAL 90° couplers can either be screwed or crimped. Crimped couplers are made from: St 37.0 S, material No. 1.0254, according to DIN 2448, dezincification-resistant brass CZ 132, or red brass RG 7. Threaded couplers are made from robust high-quality brass in compliance with DIN 8076. Technical features and installation instructions for ISOPAL accessories are provided in (...)
> More
Tee couplers - 6/10 bar
Description : ISOPAL tee couplers can either be screwed or crimped. Crimped couplers are made from: St 37.0 S, material No. 1.0254, according to DIN 2448, dezincification-resistant brass CZ 132, or red brass RG 7. Threaded couplers are made from robust high-quality brass in compliance with DIN 8076. Technical features and installation instructions for ISOPAL accessories are provided in (...)
> More
Half-shells for branches (Tees)
Description : Subsequent insulation of ISOPAL tees is carried out with two prefabricated ISOPAL half-shells. The ISOPAL half-shells are made from break-resistant glass fibre reinforced polyester. The assembly supplied with the half-shells is composed of: stainless steel hex head screws M6 x 35, a butyl rubber sealing strip, reduction rings if necessary, a brass threaded valve with plug (...)
> More
Junction muff
Description : ISOPAL flexible pipes must be insulated in the ground at the junction using a junction muff. Since the pipes supplied are very long, however, this is only required in exceptional cases. I1 or i3 kits can also be used. Technical features and installation instructions for ISOPAL accessories are provided in the ISOPAL (...)
> More
Heat-shrink end cap
Description : ISOPAL heat-shrink end caps are used on the ends of the pipes in buildings or constructions to prevent the ingress of humidity in the PUR foam caused by flooding, for example. As a variant, closure caps can be used to avoid condensation. They are made from neoprene rubber resistant to ageing. A single or double model is used, depending on the type of flexible tube. Closure (...)
> More
Wall crossing
Description : ISOPAL wall sealing rings or wall crossings prevent the penetration of water at wall feedthroughs in wells or buildings. Wall ducts must be used at every feedthrough (valve chamber, building entries, etc.) so that the pre-insulated tube can expand through the wall without damage. With sealed pressurised water systems, suitable prevention measures must be taken to avoid (...)
> More
Who are we?
Presentation
History
Our Sites
Management System
Commitments
Quality
Partnerships
Sustainable development
Our commitments
Energy efficiency
District heating and cooling networks
Products
Rigid systems
Flexible systems
Leak Detection Systems
Geolocalisation
Accessories
Applications
District heating
District cooling
Industry
Special applications
References
Services
Project management
Client support
Technical engineering services
Technical support
Training
Contact us
Contact form
Contact
|
site map
|
Legal information
Inpal © 2011.
réalisation internet axome